Question:

Air Condtioner Unit Works, Cold Air Not Coming From Vents?

by  |  earlier

0 LIKES UnLike

Recently my house started to feel warm when I had the air on. I went out side ot make sure that there my AC Unit was running, it was. I went down stairs and noticed ice on the pipe leading outside to the AC Unit. So, I changed the filter, replaced the insulation around the pipes. When I turn on the AC, the unit works outside but I don't think the blower indoors is coming on because no refreshing cold air is coming out of my vents. However, when I turn on the furnace and crank the heat the blower comes on and nice warm air comes out of the vents like it is supposed to. So, I guess what I am asking here is, can anyone give me any advice on what to do?

 Tags:

   Report

4 ANSWERS


  1. just give it a few kicks, and when it starts working start clapping.


  2. Likely bad fan relay if the blower is not coming on in cool but does in heat.

    "Might" be a bad high speed motor tap but that is not common.

    Usually the speed relay (high-cool / med-heat).  It is probably built on to the board for the furnace. Then you need a new board.

    We know the tstat is working and you have your low voltage and no safeties are tripped because the condenser unit is coming on.

    Good Luck.

  3. Get it serviced professionally. The gas may have leaked out of the cooling part of the system.

  4. You need the coils cleaned and maintanence is all.  Call a service tech.