I have had issues with this unit over the past month or so. Firing-up, running for any length of time, etc. Have even had to a dealer twice to be repaired.Would work for a while then not. Replaced the following: Ignitor, fuel filter, photo cell, pump filters, nozzle, nozzle adapter, air/fuel lines and rotor kit. Purchased a pressure gauge to check, (specs call for 3.4psi), put all back together, pressure indicated 2.0 or so; obviously, would not fire. Relief s***w adjustment made NO difference to increase pressure per gauge. I just ordered a new end cap and pump adjustment kit as now the treads are stripped from the adjustments (or lack thereof) ANY OTHER SUGGESTIONS WOULD BE HELPFUL AT THIS POINT. Thanks!
reddy heater RM60 It just shuts off after running a minimum lenghth of time
Any Suggestions???
Tags: